b1aabb7dfa
SNMP devices map onto a Steward host's detail page via _devices_for_host, which previously matched the device's `host` field (the SNMP poll target) against the Host's address/name — a coincidence of strings that breaks when the poll target differs from how the Host is recorded. Add two optional per-device config fields that decouple the binding from the poll target: • host_id — exact Steward Host UUID match (the explicit link) • steward_host — friendly bind by Host name or address (case-insensitive) An explicit binding is exclusive: a device bound to host A never implicitly matches host B by a coincidental address. No explicit binding → existing implicit `host`-string match (fully backward compatible). host_panel passes host.id and badges explicitly-bound devices. plugin.yaml documents the new fields. Tests cover explicit id/name, exclusivity, wrong uuid, and legacy fallback. Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_016Jg27rgypiW2efULXJDtMC
60 lines
2.3 KiB
YAML
60 lines
2.3 KiB
YAML
# plugins/snmp/plugin.yaml
|
|
name: snmp
|
|
version: "1.0.0"
|
|
description: "SNMP polling for network devices — switches, routers, printers, UPSes, etc."
|
|
author: "Steward"
|
|
license: "MIT"
|
|
min_app_version: "0.1.0"
|
|
repository_url: "https://git.fabledsword.com/bvandeusen/Steward-plugins"
|
|
homepage: "https://git.fabledsword.com/bvandeusen/Steward-plugins/src/branch/main/snmp"
|
|
tags:
|
|
- snmp
|
|
- network
|
|
- monitoring
|
|
|
|
config:
|
|
poll_interval_seconds: 60
|
|
# Each device is polled independently. OIDs must resolve to numeric values.
|
|
#
|
|
# `host` is the SNMP poll target (IP/hostname we query). A device also shows
|
|
# up on a Steward Host's detail page when it maps to that host. By default
|
|
# that mapping is implicit: `host` is matched against the Host's address or
|
|
# name. To bind explicitly instead — e.g. when you poll by IP but the Host is
|
|
# recorded by DNS name, or for an SNMP-only switch/PDU/UPS — add ONE of:
|
|
# host_id: "<steward-host-uuid>" # exact Host.id match
|
|
# steward_host: "switch01" # Host name OR address (case-insensitive)
|
|
# An explicit binding is exclusive: the device then maps ONLY to that host,
|
|
# never implicitly to another by a coincidental address string.
|
|
devices:
|
|
- name: "core-switch"
|
|
host: "192.168.1.1"
|
|
port: 161
|
|
community: "public"
|
|
version: "2c" # "1", "2c", or "3"
|
|
oids:
|
|
- oid: "1.3.6.1.2.1.1.3.0"
|
|
label: "uptime_centisecs"
|
|
- oid: "1.3.6.1.2.1.2.2.1.10.1"
|
|
label: "if1_in_octets"
|
|
- oid: "1.3.6.1.2.1.2.2.1.16.1"
|
|
label: "if1_out_octets"
|
|
# Example: network UPS with SNMP management card (RFC 1628 UPS-MIB).
|
|
# upsBatteryStatus values: 1=unknown, 2=batteryNormal, 3=batteryLow, 4=batteryDepleted.
|
|
# Uncomment and point at your UPS to enable.
|
|
# - name: "ups"
|
|
# host: "192.168.1.10"
|
|
# port: 161
|
|
# community: "public"
|
|
# version: "2c"
|
|
# oids:
|
|
# - oid: "1.3.6.1.2.1.33.1.2.1.0"
|
|
# label: "battery_status"
|
|
# - oid: "1.3.6.1.2.1.33.1.2.2.0"
|
|
# label: "seconds_on_battery"
|
|
# - oid: "1.3.6.1.2.1.33.1.2.3.0"
|
|
# label: "runtime_minutes_remaining"
|
|
# - oid: "1.3.6.1.2.1.33.1.2.4.0"
|
|
# label: "battery_charge_pct"
|
|
# - oid: "1.3.6.1.2.1.33.1.3.3.1.3.1"
|
|
# label: "input_voltage_dV"
|