feat(snmp): devices you add, test and read on the SNMP page (milestone 491)
The operator, reviewing SNMP on #5214: "this system looks incomplete like there's something missing from it". The one device shown was plugin.yaml's example (core-switch 192.168.1.1, community public), polled every minute; devices could only be defined by editing YAML in the image; a failed poll was logged at DEBUG and stored nowhere, so the page said "waiting for the next poll" forever; v3 ran as v2c; counters showed as lifetime totals. - Devices are rows (snmp_devices, migration snmp_001): address, port, v1/v2c community or a v3 user with auth/priv protocols and keys (secrets encrypted), presets plus custom readings, an optional host binding, and the newest poll's outcome. The YAML device list and its example are gone. - The SNMP page adds, edits and deletes them (admin, audited, with get_audit_entities so the audit log names and links a device). Readings come from presets (system uptime, interface traffic by number, UPS-MIB, Linux net-snmp) and custom "OID name [unit]" lines. - One GET per device with every OID, devices polled at once. The outcome is written to the row in words ("No reply from … within 5 s. Check the address and port, that SNMP is on, and the community"), with readings it lacks. v1's whole-request error drops that OID and asks again. SNMPv3 signs in with USM (MD5/SHA-1/SHA-2, DES/3DES/AES). - Test asks the unsaved form's device for its name, description, uptime and interfaces by number. It is an admin's explicit action; every page reads only stored rows (System 178's ruling). - Each reading has a unit; a counter is stored as a per-second rate (bytes as bit/s), a reset or wrap skipped. The page, widget and host panel say values in units and why a device is silent; the device page draws a chart per reading on a dated axis. Tests: readings and presets, the form and its secrets, v3 checks, rates, the poller against a stand-in pysnmp (one GET, v1 retry, timeout wording, USM), the pages, and an integration test of the poll writing outcomes and rates on Postgres. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
@@ -1,7 +1,7 @@
|
||||
# plugins/snmp/plugin.yaml
|
||||
name: snmp
|
||||
version: "1.0.0"
|
||||
description: "SNMP polling for network devices — switches, routers, printers, UPSes, etc."
|
||||
version: "2.0.0"
|
||||
description: "SNMP polling for network devices — switches, routers, printers, UPSes, servers."
|
||||
author: "Steward"
|
||||
license: "MIT"
|
||||
min_app_version: "0.1.0"
|
||||
@@ -12,48 +12,6 @@ tags:
|
||||
- network
|
||||
- monitoring
|
||||
|
||||
# Devices are added, tested and edited on the SNMP page (/plugins/snmp/).
|
||||
config:
|
||||
poll_interval_seconds: 60
|
||||
# Each device is polled independently. OIDs must resolve to numeric values.
|
||||
#
|
||||
# `host` is the SNMP poll target (IP/hostname we query). A device also shows
|
||||
# up on a Steward Host's detail page when it maps to that host. By default
|
||||
# that mapping is implicit: `host` is matched against the Host's address or
|
||||
# name. To bind explicitly instead — e.g. when you poll by IP but the Host is
|
||||
# recorded by DNS name, or for an SNMP-only switch/PDU/UPS — add ONE of:
|
||||
# host_id: "<steward-host-uuid>" # exact Host.id match
|
||||
# steward_host: "switch01" # Host name OR address (case-insensitive)
|
||||
# An explicit binding is exclusive: the device then maps ONLY to that host,
|
||||
# never implicitly to another by a coincidental address string.
|
||||
devices:
|
||||
- name: "core-switch"
|
||||
host: "192.168.1.1"
|
||||
port: 161
|
||||
community: "public"
|
||||
version: "2c" # "1", "2c", or "3"
|
||||
oids:
|
||||
- oid: "1.3.6.1.2.1.1.3.0"
|
||||
label: "uptime_centisecs"
|
||||
- oid: "1.3.6.1.2.1.2.2.1.10.1"
|
||||
label: "if1_in_octets"
|
||||
- oid: "1.3.6.1.2.1.2.2.1.16.1"
|
||||
label: "if1_out_octets"
|
||||
# Example: network UPS with SNMP management card (RFC 1628 UPS-MIB).
|
||||
# upsBatteryStatus values: 1=unknown, 2=batteryNormal, 3=batteryLow, 4=batteryDepleted.
|
||||
# Uncomment and point at your UPS to enable.
|
||||
# - name: "ups"
|
||||
# host: "192.168.1.10"
|
||||
# port: 161
|
||||
# community: "public"
|
||||
# version: "2c"
|
||||
# oids:
|
||||
# - oid: "1.3.6.1.2.1.33.1.2.1.0"
|
||||
# label: "battery_status"
|
||||
# - oid: "1.3.6.1.2.1.33.1.2.2.0"
|
||||
# label: "seconds_on_battery"
|
||||
# - oid: "1.3.6.1.2.1.33.1.2.3.0"
|
||||
# label: "runtime_minutes_remaining"
|
||||
# - oid: "1.3.6.1.2.1.33.1.2.4.0"
|
||||
# label: "battery_charge_pct"
|
||||
# - oid: "1.3.6.1.2.1.33.1.3.3.1.3.1"
|
||||
# label: "input_voltage_dV"
|
||||
|
||||
Reference in New Issue