fix(host_agent): SYSTIN and other board inputs past 100 °C don't set the temperature (#5759)
CI / lint (push) Successful in 2s
CI / integration (push) Successful in 1m21s
CI / unit (push) Successful in 1m26s
CI / publish (push) Successful in 17s

#5759 "VDNT-Util01 reads 114 °C: its "hottest sensor" is a Super-I/O input
with nothing wired to it". b3885c3 left out AUXTIN*, but Util01's SYSTIN
reads 114 °C too, so temp_c_max stayed at 114. A board's Super-I/O inputs
(SYSTIN, CPUTIN, AUXTIN*, PCH_*) now count only below 100 °C: a wired one
reads the board, far below that, and still counts on other boards.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
2026-10-14 17:26:02 -04:00
co-authored by Claude Opus 5.5
parent b6c4ce510d
commit 82a2a3d41f
2 changed files with 26 additions and 7 deletions
+16 -6
View File
@@ -3,6 +3,7 @@ from __future__ import annotations
import asyncio
import hashlib
import re
import time
from datetime import datetime, timezone
from typing import Any
@@ -90,15 +91,24 @@ def pick_host_address(current: str | None, reported: str | None) -> str | None:
return None
# A board's Super-I/O inputs (Nuvoton/ITE: SYSTIN, CPUTIN, AUXTIN0-4, PCH_*)
# are thermistor pins that are often left unwired, and a floating one reads a
# junk constant. Wired, they read the board, which runs far below this.
_BOARD_INPUT = re.compile(r"^(SYSTIN|CPUTIN|AUXTIN\d*|PCH_)", re.IGNORECASE)
BOARD_INPUT_CEILING_C = 100
def counts_as_hottest(label: str, celsius: float) -> bool:
"""Whether a sensor's reading may set the host's temperature (#5759).
A Super-I/O chip's AUXTIN inputs are spare thermistor pins, usually left
unconnected, and a floating one reads a junk constant (VDNT-Util01: 110 °C
flat at every load while its CPU package moved 49-87). No running host's
sensor reads 0 or below, and chips shut down before 125. Each sensor's own
row is kept either way, so a wired AUXTIN can still be charted by name."""
return 0 < celsius < 125 and not label.upper().startswith("AUXTIN")
VDNT-Util01's SYSTIN read 114 °C and AUXTIN0-4 105-112, flat at every
load, while its CPU package moved 49-87 and CPUTIN read 49: unwired
inputs. A board input at or past 100 °C is one of those; below it, it
counts. No running host's sensor reads 0 or below, and chips shut down
before 125. Each sensor's own row is kept either way."""
if not 0 < celsius < 125:
return False
return not (_BOARD_INPUT.match(label) and celsius >= BOARD_INPUT_CEILING_C)